| Common Faults and Solutions of the Fully Automatic Six-Roll Large Pill Making Machine |
|
| 2026-10-30 publish |
Automatic Six-Roll Large Pill Making Machine Common Faults and Solutions (GMP Workshop Version)
Suitable for your entire pill production line. Faults will directly affect the yield of the subsequent shell-folding and wax-dipping processes.
1. Pill weight is unstable, fluctuating up and down
Symptom: The weight of the pills fluctuates beyond the standard range, sometimes heavy and sometimes light
Reason: ① The soft material is uneven in hardness and the honey processing degree is inconsistent; ② The material bin has "bridging", and the feeding is intermittent; ③ The screw feeder is worn out and the feeding is unstable; ④ The photoelectric probe of the cutting bar is contaminated with drug powder and the signal is inaccurate; ⑤ The cutting nozzle is worn out and the thickness of the pill changes.
Solution: Re-mix the soft material; Clean the bin with bridging and blockage; Check the screw conveyor, replace if worn; Clean the photoelectric probe and recalibrate; Replace the worn cutting nozzle.
2. Sticking of the rollers, pills stuck on the pill rolling rollers and do not fall off
Symptom: Pills stick to the surface of the six rollers, difficult to remove, deformed, and with surface defects
Reason: ① The soft material is too soft and the honey usage is too high; ② The roller surface is contaminated with drug residue and not cleaned up; ③ The workshop environment temperature is too high; ④ The gap between the rolling rollers is too small.
Solution: Adjust the soft material formula and reduce the honey usage appropriately; Stop the machine, disassemble the rolling rollers, clean the roller surface with alcohol; Cool down the workshop and remove moisture;适度 increase the gap between the rolling rollers.
3. Cracking of pills (surface cracks)
Symptom: Cracks and dry cracks appear on the formed pills, making it difficult to separate and deform, with surface defects
Reason: ① The soft material is too hard and the honey usage is insufficient; ② The workshop humidity is too low and the pills dry too quickly; ③ The gap between the rolling rollers is too large, resulting in insufficient extrusion formation; ④ The rolling speed is too fast and the rolling time is insufficient.
Solution: Adjust the soft material, increase the honey usage; Increase the workshop humidity; Adjust the gap between the rolling rollers slightly; Reduce the rolling speed.
4. Connected pills, two or more pills are stuck together and cannot be separated
Symptom: The pills are stuck together after cutting and cannot be separated individually
Reason: ① The cutting knife is dull, has a notch, and the cutting is not thorough; ② The cutting delay parameter setting is unreasonable; ③ The coaxiality of the six rollers is out of alignment, and the pill rolling is not aligned; ④ The soft material is too soft.
Solution: Grind or replace the cutting knife; Adjust the cutting delay on the touch screen; Correct the coaxial position of the six rollers; Adjust the hardness of the soft material.
5. Waste pills, long material heads, large return material volume
Symptom: The output of effective pills is low, and a large amount of material heads return
Reason: ① The photoelectric sensor of the cutting bar is offset or the sensitivity is inappropriate; ② The magnetic force wheel surface is contaminated with drug powder and slips, and the feeding is asynchronous; ③ The speed of the material feeding and the rolling speed do not match.
Solution: Clean the photoelectric sensor and relearn the positioning; Clean the drug powder on the magnetic force wheel surface; Synchronize the speed of the material feeding and the rolling servo.
6. Abnormal noise and large vibration of the machine
Symptom: There are impact sounds, frictional noises during operation, and the machine shakes
Reason: ① The screws of the rolling roller seat and the brackets have been loosened due to long-term vibration; ② The bearings are lacking lubrication and worn out; ③ The magnetic force wheels are misaligned and collide with each other; ④ The synchronous belt is too tight or worn out.
Solution: Stop the machine, tighten all the fixing screws; Add food-grade lubricating oil to the bearings; Correct the gap between the magnetic force wheels; Adjust the tension of the belt, replace the damaged belt.
7. Uneven pill thickness
Symptom: The pills are uneven in thickness, flat, and irregular, and are prone to jam and burst when being separated
Reason: ① The gap between the six rollers is inconsistent, with deviations in the left and right gaps; ② The surface of the rolling rollers is scratched or has pits; ③ The rolling speed is not synchronized with the feeding speed; ④ The length deviation of the pills cut is large.
Solution: Correct the gap between the six rollers to ensure uniformity; Use an oilstone to polish minor scratches on the roller surface, replace the rolling rollers if the scratches are severe; Re-adjust the servo speed; calibrate the cutting photoelectric sensor.
9. The servo speed is unstable, fluctuating between fast and slow.
Symptom: The set speed remains unchanged, but the machine's speed fluctuates automatically, and the entire production line is out of sync.
Reason: ① The cooling holes of the servo are blocked by powder, triggering overheat protection; ② The communication terminals are loose; ③ The servo parameters have been modified; ④ Voltage fluctuations.
Treatment: Blow away the dust from the servo motor's cooling system; Tighten the communication lines; Restore the backup process parameters; If necessary, install a voltage stabilizing power supply.
10. The cutting knife does not move or cut the strips.
Symptom: The medicine strips continue to be conveyed, but the cutting knife does not cut.
Reason: ① The air pressure of the cutting knife cylinder is insufficient or there is leakage; ② The valve core of the electromagnetic valve is clogged with powder and the coil is damaged; ③ There is no signal from the photoelectric sensor that triggers the cutting strip.
Treatment: Check the air source pressure at 0.4–0.6 MPa, replace the cylinder seal ring; Clean or replace the electromagnetic valve; Clean and inspect the cutting photoelectric sensor.
Quick troubleshooting sequence (for operators to refer to)
Material condition → Air source pressure → Each photoelectric sensor → Gap between the rubbing roller and cleaning → Cutting knife condition → Servo speed matching
|
|
|